Design Success Analysis™ Reliability

Our Reliability Lab supports all the stresses required for engineering and product qualification. We execute to all applicable industry standards including JEDEC, AEC and Mil. All of our equipment is regularly calibrated using NIST-traceable tooling and methodology.
Our Reliability services include electrical stresses (ESD and Latch-up); temperature life stresses (Burn-in, both HTOL and LTOL, HTS); and environmental stresses (pre-con/reflow, temp cycle, PCT, HAST). We can accomodate both packages and wafers on most stresses. We also provide design services and fabrication for burn-in boards, HAST boards and ESD adapter boards.
Temperature Life Stresses
| Stress | Specifications |
| High Temperature Storage Life (HTOL) |
Up to 150°C (Tj) 40 channels, 3GHz BIB development available MIL-STD-883 Method 1015.9 JEDEC JESD22-A108 AEC Q100 IEC 60749-23 |
| Low Temperature Storage Life (LTOL) |
Down to -40°C BIB development available JEDEC JESD22-A108 IEC 60749-23 |
| Highly accelerated stress test (HAST) |
130°C/85% RH, biased HAST board development available JEDEC JESD22-A110 AEC Q100 |
| Temperature humidity biased (THB) |
85°C/85% RH, biased THB board development available JEDEC JESD22-A101 AEC Q100 |
Environmental Stresses
| Stress | Specifications |
| High Temperature Storage Life (HTSL) |
Up to 175°C JEDEC JESD22-A103 AEC Q100 IEC 60068-2-2 |
| Low Temperature Storage Life (LTSL) |
Down to -40°C JEDEC JESD22-A103 AEC Q100 IEC 60068-2-2 |
| Preconditioning |
Level 1 (+85°C/85% RH), 2a to 6 Including solder reflow JEDEC JESD22-A113 IPC/JEDEC J-STD-020 (MSL) |
| Moisture/Reflow Sensitivity Classification (MSLA) |
IPC/JEDEC J-STD-020 (MSL) |
| Temperature cycling (TMCL) |
Up to 165°C - Down to -65°C JEDEC JESD22-A104 AEC Q100 IEC 60068-2-14 MIL-STD-883 Method 1010.8 |
| Unbiased autoclave (PCT) |
121°C/100% RH JEDEC JESD22-A 102 AEC Q100 |
| Unbiased HAST (UHAST) |
130°C/85% RH JEDEC JESD22-A 118 AEC Q100 |
| Temperature humidity unbiased (THNB) |
Up to 85°C/85% RH JEDEC JESD22-A110 AEC Q100 IEC 60068-2-78 |
| Salt spray |
Up to 50°C/ 0.5 to 3.0 ml per 80 cm2 per hour ISO 9227 IEC 68-2-11 MIL-STD-810 Method 509,4 |
Electrical Stresses (EOS): ESD/Latch-up/OVS
| Stress | Specifications |
| HBM |
8kV over 512 pins ANSI/ESDA/JEDEC-JS-001 MIL-STD-883 Method 3015.8 AEC Q100-002 |
| MM |
2kV over 512 pins JEDEC JESD22-A115 AEC Q100-003 ESDA ANSI/ESD STM5.2 |
| CDM |
2kV JEDEC JESD22-C101 ESDA ESD STM5.3 AEC Q100-011 |
| TLP |
500V/10A ESDA ANSI/ESD STM 5.5.1 |
| IEC system level |
30KV/115A IEC 61000-4-2 |
| HMM |
30KV/115A ESDA ANSI/ESD SP 5.6 |
| Latch-up |
1A/50V over 512 pins Heat up to 150°C JEDEC JESD78 AEC Q100-004 |
| OVS and PPP |
140V/8A/10MHz IEC 60134 |
|